The ideal bridge between the A100 and A200: the A150

The A150 is a telescopic telemanipulator that has been specially developed for small to medium-sized hot cells and boxes. It bridges the classic model range between the A100 and A200 and combines maximum safety and robustness with ergonomic, comfortable handling.

Application areas of the A150:

  • as a supplement to the safety and emergency concept of nuclear power plants
  • Nuclear technology and radiopharmacy
  • Handling of hazardous substances
  • Repairs, maintenance and recovery in hot cells
  • Working indoors and in areas that are difficult to access
Maximum security
in the nuclear industry
Robustness
for longevity
Telescopic
Ideal for small to medium-sized hot cells
Ergonomic thanks to
Electrical pre-positioning of the X, Y and Z axes

A150 Manipulator data

Technical data of the A150 Manipulator

Design: two-part system (working arm + feedthrough as a unit, separable for maintenance). The A150 is optionally available with a gas-tight or non-gas-tight feedthrough, including lead shielding and/or biological shielding.
Handling capacity
12 kg
Arm length
0.6 to 1.0
Reach
up to 2 m
Weight compensation
Integrated compensation for low-force work across the entire range of motion

A150 Manipulator contact

Questions about the A150 Manipulator? Contact our experts!

A150 Manipulator Advantages

Advantages of the A150 - system integration, cost-effectiveness and future-proofing

Benefit from the combination of safety, performance and ease of use - with the A150 as a reliable partner for all demanding handling tasks.

Ergonomic operation
Weight compensation enables precise work with minimal effort
Maintenance-friendly design
Separable working arm simplifies service work and reduces downtimes.
High load capacity with compact design
12 kg handling capacity with a slim design.
Ergonomic operation
Weight compensation enables precise work with minimal effort
Maintenance-friendly design
Separable working arm simplifies service work and reduces downtimes.
High load capacity with compact design
12 kg handling capacity with a slim design.
Maximum security
Designed for radiation protection environments and the safe handling of radioactive and toxic substances.
Flexible integration
Suitable for small and medium-sized hot cells as well as existing system concepts.
Protection through „bootings“
Optional protective cover minimizes contamination from dust or particles and extends the service life.
Economical interim solution
Ideal bridge between A100 and A200 - optimized performance/cost ratio.

Advantages with Wälischmiller

Wälischmiller: Your expert for safe remote handling in the nuclear sector

Proven remote handling and manipulator systems for the nuclear industry, decommissioning, nuclear medicine and research - with proven reliability and ALARA-oriented design. We supply engineering through to service and maintenance from a single source: sophisticated engineering down to the smallest detail, clear interfaces (mechanical/electrical/control) and lifecycle support with spare parts for 30+ years. The result: plannable projects, excellent products and short distances to your technical contact.

  • Maximum safety with maximum radiation resistance
  • Excellent quality for 75+ years
  • Full-service provider with complete in-house vertical integration

The A150 combines the agility of the A100 with the performance of larger systems - with maximum user-friendliness. For many applications, it is technically the most precise solution in the mid-range segment.

A150 Manipulator request

Typical project procedure at HWM

From the initial contact to the customized solution, we accompany you transparently through every step: feasibility check & consulting, specifications/concept, design & production, acceptance, delivery and commissioning - including lifecycle service and spare parts.

Analysis & consulting Joint clarification of the requirements, operating conditions (e.g. hot cells, radiation-exposed environments) and technical framework parameters for your needs.

Concept & construction Development of a customized solution including layout, interfaces, tools and functional design for maximum precision and safety.

Production & commissioning Precise production, acceptance and professional installation and commissioning of the device on site - including training and handover for safe and efficient operation.

Further information A150 Manipulator

The A150 is a state-of-the-art telescopic manipulator designed specifically for use in hot cells, shielded work areas and nuclear technology. With electrically pre-positionable X, Y and Z axes, weight compensation and a reach of up to 2.0 m, the A150 offers maximum flexibility and efficiency - even in hard-to-reach areas or with frequent tool changes.

Thanks to its robust design and precise controls, the A150 is ideal for repairs, maintenance, recovery and safety operations in nuclear power plants or laboratories with hazardous substances. It not only ensures maximum safety for the operating personnel, but also efficient and ergonomic working under extreme conditions.

The A150 has been designed to be based on proven standard components from the A100 and A200 series. This modular architecture offers operators a decisive economic and logistical advantage: high system compatibility with a reduced number of variants.

A key added value lies in the compatibility of spare parts. As key assemblies and mechanical components have been adopted from existing platforms, the spare parts inventory can be significantly streamlined. For operators, this means

  • Lower storage costs
  • Reduced capital commitment
  • Simplified spare parts management
  • Faster availability in case of service

In addition, numerous accessories and attachments can be used across all platforms. Components such as changing devices, grippers or tools can be used within the model family. This increases flexibility when expanding or modernizing existing systems.

This design strategy also offers advantages in terms of lifecycle management. Standardized assemblies make things easier:

  • Technical training for staff
  • Maintenance and servicing processes
  • Long-term service availability
  • System upgrades within existing infrastructure

For operators of hot cells and nuclear facilities, this means long-term investment security. The A150 integrates seamlessly into existing system concepts and reduces the complexity of operations.

In short, the A150 is not only a powerful manipulation solution, but also a strategically optimized platform within the system family.

Questions and answers A150 Manipulator

A150 Manipulator in action: these customers are convinced

What applications is the A150 suitable for?

For nuclear power plants, radiopharmacy, nuclear technology, maintenance work in hot cells and the handling of hazardous substances.

What is the handling capacity of the A150?

The handling capacity is 12 kg.

Can the gripper be changed remotely?

Yes, the change takes place directly in the cell via a sealed change device.

Is the A150 available gas-tight?

Yes, optionally with gas-tight feed-through and additional lead or biological shielding.

Can the manipulator be protected against contamination?

Yes, with so-called bootings - special protective covers for the working arm.

Is the 150 resistant to radiation?

Yes, the Wälischmiller Engineering Manipulator System HWM A150 is designed for special operating conditions. Radiation-resistant, acid-resistant and corrosion-resistant materials are used here. Only first-class materials are used after they have undergone a high-quality surface treatment.

Similar products

Take a look at similar products

Produktbild A1000

Power manipulator A1000

The A1000 power manipulator handles heavy loads of up to 200 kg precisely and reliably. The device is radiation-resistant and modular.

VNE80/90

The VNE 80 and VNE 90 are low-friction, gas-tight manipulators for use in laboratories and fuel element reprocessing plants.
Produktbild A200

A200 Manipulator